Trango Systems, Inc. GigaPlus User Manual Rev 3.1 128
Capacity License Activation
Activate the traffic capacity license if needed. License keys are typically installed at the
factory prior to shipment. Should the operator wish to re-enter the license keys, use the
license command as shown below
(CLI-config)# license 2 <alphanumeric key>
License: License 2
SUCCESS
Automatic Transmit Power Control (ATPC) Configuration (optional)
Configure the Automatic Transmit Power Control (ATPC) if required. ATPC is typically
only required if the link is so short that the max transmit power cannot be used due to
receiver overload, or for regulatory reasons.
First check the ATPC status. If the ATPC is off then the ATPC can be enabled using the
atpc enable on command. In the example below the max power is currently 19 dBm
(CLI-config)# atpc
ATPC Enable: on
ATPC Step Size: 1
ATPC Max Power: 19.00
Next, set the ATPC max power based on the highest modulation that will be used. In the
example below, the highest transmit power that will be used is +17 dBm, so the atpc
max_power is set accordingly.
(CLI-config)# atpc max_power 17
ATPC max power: 17.00
SUCCESS
(CLI-config)# atpc
ATPC Enable: on
ATPC Step Size: 1
ATPC Max Power: 17.00