Trango Systems, Inc. GigaPlus User Manual Rev 3.1 173
odupower
odupower < on| off >
Default: OFF
Configuration Storage: Yes
odupower without any parameter will display the current status of ODU
power .
The command is used to Turn ON/OFF odupower.
The ODU is powered from the IDU over the IF cable with -48VDC
It is recommended to turn off the ODU power during initial installing of the
ODU on the tower and other maintenance
The response time for ODU power ON will vary depending upon the ODU
model. It is longer for HP ODUs
The command is used to set the odurx gain control loop in the system. This
controls the receive level into the IDU from the ODU and keeps the
received level within a predefined range. This helps to improve MSE and
maintain better system performance in fading conditions.