Trango Systems, Inc. GigaPlus User Manual Rev 3.1 161
freq
SYNTAX
freq [tx_freq in MHz]
Default: no default frequency. 0
Configuration Storage: Yes
The setting of frequency can be to the 250 kHz resolution.
EXAMPLE: freq 17727.5
freq without any parameter will display the current Tx and Rx frequency for
the ODU.
DESCRIPTION
Sets the ODU transmit frequency and then the receive frequency, based on
the freq_duplex spacing. In some cases the IDU IF frequency is changed as
well (Giga-ODU-xx). In general, for HP ODUs there is no limitation on the
Certain IDU/ODU PLL synthesizers are programmed for each and every
individual frequency.
GigaPlus supports model 6, 6E, 11, 11E, 15, 18, 18E, 23, 23E of SP ODU’s
And 6-38Ghz HP ODU’s
freq_duplex
SYNTAX
freq_duplex [duplex]
Default: 0
Configuration Storage: Yes