Trango Systems, Inc. GigaPlus User Manual Rev 3.1 147
acm mod is used to update MSE value for degrade or improve threshold
table. The new threshold values should be effect immediately upon
execution.
Depending on the speed set, certain modulations are not available. For
example, when initial speed modulation is at QAM256, the available
modulation levels and thresholds are:
profile
mse_im
mse_de
QPSK
-20.3
-17.10
16QAM
-25.3
-18.5
64QAM
-29.2
-24.3
256QAM
-32.1
-27.2
Note: the default values provided ensure hitless transitions between
modulation levels. Any changes made by the user cannot be guaranteed to
result in hitless modulation transitions.
alarm
SYNTAX
alarm
alarm <alarm1 | alarm2> <on/off>
Default: alarm 1 OFF, alarm 2 OFF
Configuration Storage: No
alarm without any parameter will display the current status for both alarm1
and alarm2
alarm is a system-level command.
DESCRIPTION
User may specify alarm1 or alarm2 as the action in the threshold settings.
This command is used to turn off the alarm after the alarm has been