Trango Systems, Inc. GigaPlus User Manual Rev 3.1 187
speed
SYNTAX
speed <bandwidth> <modulation>
<bandwidth>: 4,5,7,8,10,12,14,20,25,28,30,40,50,56,80
<modulation>: qpsk, qam16, qam32, qam64, qam128, qam256
Default: bandwidth 30, QAM32
Configuration Storage: Yes
speed without any parameter will display the current speed setting
DESCRIPTION
Load the corresponding the modem binary and configure Tx and Rx
bandpass filters.
The speed command will also configure the modem protection mode
based on the system_mode configuration. Only when the 1+1 HSB mode is
set, the modem may be configured as working or protection mode.
Binaries selection for the speed command is based on 5 different
configuration: tdm_mode, acm enable, modulation and bandwidth.
Making changes via the tdm_mode, or acm enable commands will
require a subsequent re-load of the speed setting for proper operation.
Speed Setting
(Actual BW)
Modulation
IF RX
LPF (MHz)
IF TX
LPF (MHz)
Total
Capacity
Symbol
Rate
License key

Table of Contents