Trango Systems, Inc. GigaPlus User Manual Rev 3.1 184
rssi
SYNTAX
rssi <iteration>
Iteration range from 1-99 seconds
Default: default iteration = 1 second
Configuration Storage: NO
rssi without any parameter will display the current mse value
DESCRIPTION
rssi command is used to monitor the received signal level. It is used to
monitor the link, based on the specified duration. CLI prompt will not be
accessible while rssi command is running.
RSSI value range should be between 90 and -30
For some SP ODUs, the RSSI value will not display below -65 dBm
accurately, so for antenna alignment purposes the MSE can be used as a
guide until the signal is acquired. See the Antenna Alignment Section for
more information
siglevel
SYNTAX
siglevel
Default: N/Q
Configuration Storage: No
Siglevel will display the signal level related parameter for modem 1
DESCRIPTION
This command is used to assist debugging any signal path related issue.
IDU RSSI: idu rssi on the modem level.
Nomralize MSE/Radial MSE:
Norm-MSE = Radial MSE phase noise residue is minimal