Trango Systems, Inc. GigaPlus User Manual Rev 3.1 185
Norm-MSE > Radial MSE there is some amplitude noise (AM
distortion)
Norm-MSE < Radial MSE phase noise residue exist, that the PLL did
not fully correct
Uncorrect Block: Error reported by modem when passing traffics.
Power sensors: used to make sure TX power accuracy. Some models
uses only IF while other using only the RF values.
Odu attn: Make sure the attenuators are been set correctly.
Note: Block counter & uncorrect block counter are accumulative
values since the last link establishment. They are collected on a 20
second periodic basis.
EXAMPLE
(CLI-view)# siglevel
IDU RSSI: 0
Normalized MSE: -348
Radial MSE: -340
LDPC Decoder Stress: 0
External AGC: 1604
Carrier Offset: 2466
Rx Symrate: 49500732
Block Counter: 0
Uncorrect Block: 0
LDPC Avg Iteration: 0
Output corrected bytes: 0
Return Loss: 0x0000
Tx Power alarm: ok
Tx PA alarm: ok
PA on/off alarm: on
Tx Power Range alarm: ok
Tx Power actual: 20.00
Rx Power actual: -23.00
Channel test: Pass
Telemetry debug: Fail
(CLI-view)#