EasyManua.ls Logo

Trango Systems TrangoLINK GigaPlus - Sync; Sync_State

Trango Systems TrangoLINK GigaPlus
255 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Trango Systems, Inc. GigaPlus User Manual Rev 3.1 192
utilization.
sync
SYNTAX
sync
Default: N/A
Configuration Storage: N/A
sync without any parameter will perform synchronization procedure
between Active and Standby unit
sync command only allowed to be initiated on Active unit.
DESCRIPTION
sync is used to perform synchronization procedure to sync up
configuration parameters between Active and Standby units. There
are some parameters which are independent of utype and therefore,
will not be synchronized with this command. The following
commands are the ones that, if executed, prevent achieving sync
with the Standby unit:
Alarm, alignment, cableloss, fanctrl, ibm, ipconfig, license key,
loopback mode, opmode, tftpd and traps.
sync_state
SYNTAX
sync_state
Default: N/A
Configuration Storage: N/A
sync_state without any parameter will display synchronization status

Table of Contents