Trango Systems, Inc. GigaPlus User Manual Rev 3.1 148
triggered, or turn on an alarm remotely.
Alarms are also set by the system internally when certain configured
thresholds are exceeding its expected range.
atpc
SYNTAX
atpc
atpc enable < on| off >
atpc max_power <0-30>
atpc step_size <0-5>
Default: enable OFF, max power 17 dBm, step size 1
Configuration Storage: Yes
atpc without any parameter will display the current status of ATPC feature
DESCRIPTION
atpc is used to display ATPC features parameters including ATPC step size,
ATPC enable, and ATPC max power.
atpc enable: ATPC is used to automatically adjust the remote end ODU
transmit power in order to maintain the desired level of RSSI (within 2 dB
range of targetrssi) at the local end. This feature will work only when both
local and remote radio are enabled.
atpc max_power: Set the maximum ATPC power. This parameter is used
only when the ATPC is enabled.
User cannot execute the power command when ATPC is turned on. The
system will adjust the power automatically based on the “max_power” and
“step_size”.
atpc step_size: Specified the step size for each of the ATPC command for
power up/down