Trango Systems, Inc. GigaPlus User Manual Rev 3.1 168
The license key is specific to each unit (management port Ethernet MAC
address) and is not transferable. The PDH key enables all T1/E1 ports on
the IDU.
Please refer to valid speed profiles.
link_history
SYNTAX
link_history
Default: N/A
Configuration Storage: No
DESCRIPTION
This command is to display if the link history and the link steady flag.
Link history: contains the number of link up/down occurred since the
system bootup and this number does not get reset until the radio reboots.
Link steady: current status of link steady flag. Defined to be
approximately 40 seconds after the link has been established.
linktest
SYNTAX
linktest <iterations>
Iteration range from 1-99 seconds
Default: default iteration = 1 second