Trango Systems, Inc. GigaPlus User Manual Rev 3.1 199
threshold value allows the user to set a threshold for the following
parameters between a value of -100 and 100.
Parameters
0- RSSI
1- MSE
2- BER
3- FER
4- IDU_temp
5- ODU_temp
6- In port utilization
7- Out port utilization
threshold action allow specific action to be taken if the threshold set in
threshold value is exceeded. Actions are:
0- No action
1- Alarm1 on front panel closure
2- Alarm2 on front panel closure
3- SNMP trap
4- Switchover to standby unit
5- Rapid Port Shutdown (RPS)
The utilization rate is expressed as percentage of the current max
speed based on the modulation.
trap
SYNTAX
trap
trap enable <trap #> <on | off>
trap ip <trap #> <ip_addr>
Default: see table 6.5