Trango Systems, Inc. GigaPlus User Manual Rev 3.1 89
units. If failover is enabled on the standby units while the actives are still in the
election period, the active role will be taken by the radio with the higher MAC
address.
8) The display for the Link status at the top of the page should change to show both
Active and Standby units “Green” for all 4 units.
9) The system is now setup in 1+1 mode. If the main link fails, the ports will be shut
down on the main link and the traffic will flow through the standby link, allowing
connected switches to re-route the traffic.
10) Click the Config Save button at the lower left of any webpage This must be
done on both sides of the link.