EasyManua.ls Logo

Vaisala WINDCAP WMT700 Series - Appendix E. WMT700 NMEA MWV Profile; E.1 Configurable Parameters

Vaisala WINDCAP WMT700 Series
210 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter Name Default
Value
Allowed Values Units Description
wndCover
4 0 ... 20 seconds s Defines how long WMT700
continues to report the last
valid wind value if wind
measurement fails (for
example due to snow or birds).
0 means that if measurement
fails, WMT700 reports missing
measurement data
immediately.
wndDirOffset
0 -180 … 180
degrees
Deg User-defined wind direction
oset.
wndGainLo
1 % Wind tunnel tests show that
the bird cage systematically
lowers the wind speed reading
by 1.5 % (cage) or 2.5 % (cage
and net). The wndGainLo
parameter can be used to
compensate for wind speed
gain correction for the bird
cage.
S wndGainLo,1.015
wndGustTime
3 0.25 … 10
Resolution: 0.25
s Averaging time for wind
minimum and maximum in
seconds.
wndOrientation
0 0 = Array facing
up
1 = Array facing
down
Orientation of the transducer
arms of WMT700.
wndRate
1 1 = 4 Hz
2 = 8 Hz
Hz Wind vector update rate. For
best performance in wind
speeds over 50 m/s, Vaisala
recommends the 4 Hz rate.
wndUnit
0 0 = m/s
1 = mph
2 = km/h
3 = knots
Wind speed unit. This
parameter aects data
messages sent through serial
interfaces but has no impact
on analog output.
wndVector
0 0 = Scalar
averaging
1 = Vector
averaging
Wind averaging method
Appendix D – Configuration Parameter Descriptions
191

Table of Contents

Other manuals for Vaisala WINDCAP WMT700 Series

Related product manuals