PROBLEMS WITH FILM STACKING
PROBLEM
When running multiple prints on film, stacking
problems may occur.
CAUSE
When film exits the machine it is very hot and
flexible. After the first film print exits the
machine, the film that follows may stick to the
previous print. This can cause the film to roll
up and block the exit.
SOLUTION
Adjust diagnostic code 0760 to increase the
delay between film copies. This will impact
throughput of film only.
REQUIREMENTS FOR FIELD RESOLUTION
• DOCUMENTATION
N/A
• TAG
11/8
• PART NUMBERS
N/A
• CUT IN SERIAL NUMBER
N/A
LOW SOLID AREA DENSITY AT
INSTALL
PROBLEM
At install it is difficult to attain 1.0 solid area
density.
CAUSE
This symptom is a developer/toner materials
package phenomena that has to do with aging.
SOLUTION
There is no fix for this problem other than to
allow the material to age. After 500 to 1000
linear feet the solid area coverage will recover.
NOTE: DO NOT USE 09 21 6 to adjust image
density!!! Adjust only the image density in
diagnostic 09 21 4.
REQUIREMENTS FOR FIELD RESOLUTION
• DOCUMENTATION
N/A
• TAG
N/A
• PART NUMBERS
N/A
• CUT IN SERIAL NUMBER
N/A
INTERMITTENT EXTRA PRINT
PROBLEM
Intermittently an extra print is printed. The
extra print will be partially the requested print
and partially one of the internal test patterns.
CAUSE
Electrical noise that is being injected into the
system is causing the system to print this
strange print. This noise is caused by either a
contaminated scorotron that Is arcing or the
scorotron leads breaking down. No error code
is produced but the system prints a second
print correctly because it knows the first one
failed.
SOLUTION
Clean the suspect scorotron and grid.
Replace the grid or pins if required. Replace
the Scorotron endblock and leads by installing
a scorotron end block kit (600K58730)
REQUIREMENTS FOR FIELD RESOLUTION
• DOCUMENTATION
N/A
• TAG
N/A
• PART NUMBERS
600K58730 Scorotron Endblock Kit
. CUT IN SERIAL NUMBER
N/A
8830
1/98
6-43
Service Notes