3.1 MACHINE RUN CONTROL (2 OF 2)
VIEW: FRONT TOP (DOOR OPEN)
MACHINE RUN CONTROL DIAGNOSTIC CODES
(0203) BILLING METER: OUTPUT
(0300) JUMP O: RESTARTS THE IOT.
( 0360 ) NVM RESET TO NOMINAL NVM:
[1 ]. RESETS ALL OF THE BASIC NVM TO NOMINAL FOR A US MARKET
CONFIGURATION (DOES NOT AFFECT THE AUDITRON ACCOUNTS). IT
REQUIRES ENTER TO AUDITRON ACCOUNTS). IT REQUIRES ENTER TO
CONFIRM.
[2]. ALLOWS THE TECH REP TO SEE AND THEN CHANGE THE ELECTRONIC BILLING
METER TO ANY DESIRED VALUE. IT REQUIRES ENTER TO CONFIRM THE NEW
VALUE AND AFFECTS THE THREE LOCATIONS OF THE NVM LOCATION
PRINT COUNTER.
[3]. RESETS ALL OF THE BASIC NVM TO NOMINAL CONDITION FOR AN E0. 220 VOLT
MACHINE (DOES NOT AFFECT THE AUDITRON ACCOUNTS). IT REQUIRES START-
TO CONFIRM AND IS IDENTICAL TO [1] ABOVE EXCEPT FOR THE FOLLOWING
LOCATIONS: 21.22.23.29.89, AND 9A.
AFTER RESETTING NVM TO NOMINAL VALUES. THE TECH REP SHOULD
EXECUTE [1031] TO UPDATE OILER WEB COUNTERS IF THE INSTALLED WEB
IS NOT NEW.
[0361] WATCH DOG TIMER: RESTARTS THE IOT.
[ 0362 ] TIMEOUT INTERVAL FOR EXITING DIAGNOSTICS
[ 0363 ] NVM RESET: RESETS TO NOMINAL THE LOCATIONS THAT
DO NOT MATCH BETWEEN DATA AND SHADOW.
[0364] NVM RESET: RESETS CHECKSUM (DOES NOT AFFECT NVM
INPUT POWER BLOCK
VOLTAGE
+26 VDC (BULK)
DC COM
TEST POINT
LVPS (A6) J3-18
LVPS (A5) J3-17
GF
1.2
1.2
NOTES:
REFER TO THE CONTROLLER SERVICE MANUAL OR
TO THIRD PARTY SERVICE DOCUMENTATION TO
SERVICE THE CONTROLLER.
MAIN PWB (A3) J307 CONNECTS TO ONE OF TWO
RIBBON CABLES. RIBBON CABLE (A) CONNECTS
TO XEROX CONTROLLER AT P5. RIBBON CABLE
(B) CONNECTS TO NON-XEROX CONTROLLER AT
PANEL MOUNTED J1.
REFER TO THE FOLDER SERVICE MANUAL FOR A
COMPLETE LISTING OF F1.XX FOLDER CODES.
[0365] NVM PRINTOUT: PRINTS OUT THE ENTIRE CONTENTS OF NVM (IN HEX FORMAT). THE
BAUD RATE IS DEPENDENT UPON NVM.
[0391] SERVICE EVENT DISPLAY: DISPLAYS THE LAST 20 EVENTS THAT HAVE OCCURRED ON
THE LCD DISPLAY. AN EVENT IS DEFINED AS A FAULT. A POWER-UP OF THE IOT. OR A
DIAGNOSTIC POWER-UP OF THE IOT. THE INFORMATION THAT IS DISPLAYED I
INCLUDES HOW MANY EVENTS AGO. THE EVENT NUMBER IN A HUMAN READABLE
FORM (C1XX OR 'NORM POWER UP' OR "DIAG POWER UP*). AND THE BILLING METER
AT THE TIME OF THAT EVENT.
[0392] SERVICE HISTORY DISPLAY: DISPLAYS THE EVENT NUMBERS. AS WELL AS THE
TOTALS FOR EACH EVENT. ONLY THOSE EVENTS WHICH HAVE OCCURRED WILL BE
DISPLAYED. IN A HUMAN-READABLE FORM.
YOU WILL BE PRESENTED WITH THE BILLING METER COUNT AT WHICH THE HISTORY
WAS LAST CLEARED. YOU WILL BE ABLE TO SCROLL THROUGH THE LIST OF EVENTS
USING THE NEXT AND PREVIOUS KEY. WHEN EXITING FROM THIS DIAGNOSTIC. YOU
WILL BE PROMPTED TO CLEAR THE FAULT HISTORY. IF YOU CHOOSE TO CLEAR THE
FAULT HISTORY. THE CURENT BILLING METER WILL BE RECOROED AND PRESENTED
THE NEXT TIME [0392] IS RUN.
[1403] FOLDER COMMUNICATIONS LOOPBACK TEST FOR FOLDER RS-232C PORT
COMMUNICATIONS CABLE. AND FOLDER.
[1404] CONTROLLER COMMUNICATIONS TEST.
8830
1/98
7-25
Chain 3 Machine Run Control