February 2013
6-135
ColorQube® 9303 Family
dC131
General Procedures/Information
445-013 badJet5 Value identifies the location of
a jet that will not be used
Set with bad jet for-
mat: HCJet
Read - XYZZZ
X = head (1-4): Y =
Colour (CMYK = 1-
4) Z = Jet number
(1-220)
Example 23044 =
head 2, Y, jet 44
Clear by writing 0
Range = 0 to 65,535
0
445-014 badJet6 Value identifies the location of
a jet that will not be used
Set with bad jet for-
mat: HCJet
Read - XYZZZ
X = head (1-4): Y =
Colour (CMYK = 1-
4) Z = Jet number
(1-220)
Example 23044 =
head 2, Y, jet 44
Clear by writing 0
Range = 0 to 65,535
0
445-015 badJet7 Value identifies the location of
a jet that will not be used
Set with bad jet for-
mat: HCJet
Read - XYZZZ
X = head (1-4): Y =
Colour (CMYK = 1-
4) Z = Jet number
(1-220)
Example 23044 =
head 2, Y, jet 44
Clear by writing 0
Range = 0 to 65,535
0
445-016 badJet8 Value identifies the location of
a jet that will not be used
Set with bad jet for-
mat: HCJet
Read - XYZZZ
X = head (1-4): Y =
Colour (CMYK = 1-
4) Z = Jet number
(1-220)
Example 23044 =
head 2, Y, jet 44
Clear by writing 0
Range = 0 to 65,535
0
Table 4 IOT NVM (IME) ID Range 440 to 459-xxx
NVM ID NVM Name NVM Description Settings Default
445-017 badJet9 Value identifies the location of
a jet that will not be used
Set with bad jet for-
mat: HCJet
Read - XYZZZ
X = head (1-4): Y =
Colour (CMYK = 1-
4) Z = Jet number
(1-220)
Example 23044 =
head 2, Y, jet 44
Clear by writing 0
Range = 0 to 65,535
0
445-018 badJet10 Value identifies the location of
a jet that will not be used
Set with bad jet for-
mat: HCJet
Read - XYZZZ
X = head (1-4): Y =
Colour (CMYK = 1-
4) Z = Jet number
(1-220)
Example 23044 =
head 2, Y, jet 44
Clear by writing 0
Range = 0 to 65,535
0
445-019 badJet11 Value identifies the location of
a jet that will not be used
Set with bad jet for-
mat: HCJet
Read - XYZZZ
X = head (1-4): Y =
Colour (CMYK = 1-
4) Z = Jet number
(1-220)
Example 23044 =
head 2, Y, jet 44
Clear by writing 0
Range = 0 to 65,535
0
445-020 badJet12 Value identifies the location of
a jet that will not be used
Set with bad jet for-
mat: HCJet
Read - XYZZZ
X = head (1-4): Y =
Colour (CMYK = 1-
4) Z = Jet number
(1-220)
Example 23044 =
head 2, Y, jet 44
Clear by writing 0
Range = 0 to 65,535
0
Table 4 IOT NVM (IME) ID Range 440 to 459-xxx
NVM ID NVM Name NVM Description Settings Default