February 2013
6-227
ColorQube® 9303 Family
dC131
General Procedures/Information
616-010 powersaver idle-
time
Defines time in "normal" mode
where system has been idle to
enabled transition into power
saver.
Range = 0 to 255 5
616-011 power saver in
mode time
Defines time in "mode 1"
before transitioning to "mode
3" for appropriate configura
-
tions.
Range = 0 to 255 60
616-012 power saver
power off time
Defines time in "lowest" power
saver mode before powering
off.
Range = 0 to 255 45
616-013 Date Display For-
mat
Defines date display format 0
= mm/dd/yy, 1 = dd/mm/yy, 3 =
yy/mm/dd
Range = 0 to 3 0
616-014 system install
phase
Defines system's current
installation phase.
Range = 0 to 4 2
616-015 Not displayed -SMFCustomerServiceNumber Range = 0 to 0 0
616-016 power up reason Defines reason for previous
power off.
Range = 0 to 6 1
616-017 Contention Algo-
rithm
Defines the order algorithm for
queues/ contention: FIFO vs.
priority
Range = 0 to 1 1
616-018 Extra Time Amount of additional time after
power up before system can
enter power saver.
Range = 0 to 5 5
616-019 system mode Defines system's overall mode Range = 0 to 12 0
616-020 auto configura-
tion enabled
Determines if the system runs
through auto configuration,
detect at power on. 0 = False,
1 = True
Range = 0 to 1 1
616-021 line voltage Defines system line voltage
0=Unknown, 1 = 100V, 2 =
115V, 3 = 230V
Range = 0 to 3 2
616-022 line frequency Defines system line frequency
0 = 50Hz, 1 = 60Hz
Range = 0 to 1 1
616-023 Not displayed system serial number Range = 0 to 0 0
616-024 serial number
enabled
Determines whether serial
number has been set. 0 =
False, 1 = True
Range = 0 to 1 1
616-025 promotion time Defines time interval for
increasing job's priority based
on time in system.
Range = 15 to 1440 120
Table 20 CCS NVM ID 616-xxx
NVM ID NVM Name NVM Description Settings Default
616-026 auto promotion
enabled
Determines whether to
increase job priority longer job
is in system. 0 = False, 1 =
True
Range = 0 to 1 1
616-027 previous market
region
Defines previous market
region 0=USCO, 1 = XCL, 2 =
FX, 3 = FXAPO, 4 = ACO, 5 =
RX
Range = 0 to 5 0
616-028 modeChangeCli-
entId
Defines client who did the
most recent system mode
change.
Range = 0 to 9994 16
616-029 latest EOD event Defines last day that an end of
day was reached.
Range = 0 to
4294967295
0
616-030 previous product
config
Defines previous product con-
figuration (All Products)
Range = 0 to 255 106
616-031 previous line fre-
quency
Defines previous line fre-
quency 0 = 50Hz, 1 = 60Hz
Range = 0 to 1 1
616-032 previous line volt-
age
Defines previous line voltage
0=Unknown, 1 = 100V, 2 =
115V, 3 = 230V
Range = 0 to 3 2
616-033 nvm copyright
years
List of system's copyright
years.
Range = 0 to
4294967295
0
616-034 desired install cli-
ent
Defines current client of sys-
tem installation.
Range = 0 to 255 0
616-035 remoteIntrusive-
DiagEnabled
Determines whether remote
intrusive diagnostics is
enabled. 0 = False, 1 = True
Range = 0 to 1 1
616-036 value added
reseller
Range = 0 to 255 255
616-037 GMT Offset Used by platforms to insure
system clocks are set to cor
-
rect time zones.
Range = -43200 to
50400
0
616-038 NC OnlineNvm Determines whether ESS is
On (Off) line. 0 = False, 1 =
True
Range = 0 to 1 1
616-039 Job Hold Time Max time a job can be held
before it is deleted by the sys
-
tem
Range = 0 to 7200 4320
616-040 Job Hold Timer
enabled
SA/KO setting to enable/dis-
able hold job timer
Range = 0 to 1 1
616-041 ScanToFilein-
stalled count
Counter used for secure install
and remove operations of the
optional features
Range = 0 to 65535 0
Table 20 CCS NVM ID 616-xxx
NVM ID NVM Name NVM Description Settings Default