3.4 Motion Parameter Details
3.4.2 Setting Parameter Details
3-48
Setting Precautions
• The speed limit can be changed during operation. However, if an incorrect setting is made
during operation, it may affect the movement of the machine.
• If this parameter is set to 0, no speed limit check is performed.
• If a value outside the valid setting range is set for the speed limit, no limit processing is per-
formed. (Operation is the same as for a set value of 0.)
• If a speed reference is issued that exceeds the set speed limit when any of the following
motion commands is executed, a reference is issued to the slave SERVOPACK with the value
of the speed limit. In this case, the following warning also occurs.
Applicable commands: POSING, EX_POSING, ZRET, FEED, STEP, VELO, and EX_FEED
Warning: Setting Parameter Error (IL02, Bit 1)
• If a speed reference is issued that exceeds the set speed limit when any of the following
motion commands is executed, the following alarm occurs and the axis is stopped.
Applicable commands: INTERPOLATE, LATCH, and PHASE
Alarm: Excessive Speed (IL04, Bit 8)
Torque/Force Limit
Torque/Force Limit
Set the torque limit. The same value is used in both the forward and reverse directions.
This setting is used when a torque limit is required at a certain time during machine operation.
Setting Precautions
The unit that is set in the Torque Unit Selection bits (OW03 bits C to F) is used for this
parameter.
Second Speed Compensation
Second Speed Compensation
Set the speed feedforward compensation when the INTERPOLATE (Interpolation), LATCH
(Latch), or PHASE (Issue Phase Reference) motion command is executed.
Setting Precautions
• The unit that is set in the Speed Unit Selection bits (OW03 bits 0 to 3) is used for this
parameter.
• The setting unit for the OW31 setting parameter (Speed Compensation) is always
0.01%. The unit for this parameter, however, is set in the Speed Unit Selection bits. When this
parameter is used at the same time as OW31, speed compensation is performed
twice.
Applications of this parameter include pressing operations to stop movement and holding
workpieces.
Register
Address
Name
Setting
Range
Setting Unit Default Control mode
OL14
Torq u e/Force Limit
-2
31
to 2
31
−1
The unit that
is set in the
Torque Unit
Selection bits
is used.
30,000
Register
Address
Name
Setting
Range
Setting Unit Default Control mode
OL16
Second Speed Compensation
-2
31
to 2
31
−1
The unit that
is set in the
Speed Unit
Selection bits
is used.
0
SVC
SVC