EasyManua.ls Logo

YASKAWA SVC - Main Command Details

YASKAWA SVC
623 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10.4 Main Commands and Subcommands
10.4.3 Main Command Details
10
Inverter Operation
10-21
10.4.3
Main Command Details
Each command and its parameters are described below.
No Command
Description
No command to be executed
Setting Parameters
Monitor Parameters
Inverter Drive Control
Description
Sends commands to the Inverter and monitors the Inverter.
Note: If the Inverter Drive Control command is switched to another command during its execution, the Inverter
retains the last data and continues operation. The MPE720 retains the last data for the monitor parame-
ters because I/O between the SVC Function Module and Inverter are stopped. The Status monitor
parameter, however, will be updated for any command being executed except Transmission Reference.
If you change the command to No Command during operation, the motor will stop for a SERVO-
PACK but it will not stop for an Inverter.
Be aware that the operation for an Inverter is different from the operation for a SERVOPACK.
Name Register No. Setting Range Remarks
Command OW08 0 to 8 00: No Command
Name Register No.
Setting
Range
Remarks
Command Response Code IW08 0 to 8 00: No Command
Command Status IW09 Bit
Bit 0 (Command execution
flag)
Always
OFF
Bit 3 (Command error com-
pleted status)
Always
OFF
Bit 8 (Command execution
completed status)
Always
ON
M-III Inverter Command
Status
IL2A Bit Inverter operating status
M-III Command Status IW2C Bit Inverter command processing status
Inverter Alarm Code IW32 0 to FFFFH Inverter alarm code
Important

Table of Contents

Related product manuals