10.4 Main Commands and Subcommands
10.4.3 Main Command Details
10-22
Setting Parameters
Monitor Parameters
Name Register No.
Setting
Range
Remarks
Mode Settings 1 OW01 Bit
Command OW08 0 to 8 01: Inverter Drive Control
Output Data Option Selec-
tion
OW0C Bit
Input Data Option Selection OW0D Bit
Input Command OW10 Bit
Speed Reference OW11 −−
Torque Reference OW12 −−
Torque Compensation
(Option)
OW13
Enabled when the Output Data Option Selection
(OW0C), bit 0 is ON.
Analog Output Terminal 1
Output
OW14
Enabled when the Output Data Option Selection
(OW0C), bit 1 is ON.
Analog Output Terminal 2
Output
OW15
Enabled when the Output Data Option Selection
(OW0C), bit 2 is ON.
Terminal Output OW16
Enabled when the Output Data Option Selection
(OW0C), bit 3 is ON.
PID Target OW17
Enabled when the Output Data Option Selection
(OW0C), bit 4 is ON.
Pulse Train Output OW18
Enabled when the Output Data Option Selection
(OW0C), bit 5 is ON.
V/f Gain OW19
Enabled when the Output Data Option Selection
(OW0C), bit 6 is ON.
Command Selection OW1B
Enabled when the Output Data Option Selection
(OW0C), bit 8 is ON.
Name Register No.
Setting
Range
Remarks
Warning IL02 Bit
Alarm IL04 Bit
Command Response Code IW08 0 to 8 01: Inverter Drive Control
Command Status IW09 Bit
Bit 0 (Command execution
flag)
ON while the com-
mand is being exe-
cuted
Bit 3 (Command error com-
pleted status)
ON when an error
occurs during
command pro-
cessing
Bit 8 (Command execution
completed)
OFF during com-
mand execution,
and ON when
command execu-
tion is completed.
Input Data Option Selection
Monitor
IW0D Bit
Output Frequency IW11 −−
Output Current IW12 −−
Motor Speed (Option) IW13
Enabled when Input Data Option Selection
(OW0D), bit 0 is ON.
Torque Reference (Option) IW14
Enabled when Input Data Option Selection
(OW0D), bit 1 is ON.
Encoder Count PG1 IW15
Enabled when Input Data Option Selection
(OW0D), bit 2 is ON.
Continued on next page.