10.1 Connection Specifications
10-2
10.1
Connection Specifications
The following table provides the specifications required when connecting Inverters through
MECHATROLINK.
*1. Main commands and subcommands can be used.
*2. Only main commands can be used.
Item Specification
Applicable models
A1000: S1018 or later using the SI-ET3 Communications Option Card
V1000: S1022 or later using the SI-ET3/V Communications Option Card
Number of Inverters that can be
connected
4 max.
Transmission cycle 125 μs, 250 μs, 500 μs, or 1 ms
Interface
Fixed parameters (To set application conditions)
Setting parameters (To update references and output data)
Monitor parameters (To update monitored or input data)
Self-configuration Function Available
Others
Conforms to the MECHATROLINK-III standard inverter profile specifica-
tions (64-byte
*1
or 32-byte
*2
).