7.4 SERVOPACK Parameter Data Flow
7.4.4 When SERVOPACK Parameters Are Saved
7
Making Settings for Motion Control with the MPE720
7-25
7.4.4
When SERVOPACK Parameters Are Saved
The flow of data for the SERVOPACK parameters when parameters are saved on the SERVO-
PACK Tab Page is shown below.
Refer to the following section for the procedure to display the SERVOPACK Tab Page.
7.3.1 Displaying and Setting Motion Parameters on page 7-19
The MPE720 writes all of the parameters that are displayed on the SERVOPACK Tab Page for
the relevant axes to the following locations.
Hard disk drive of the PC
SDRAM in the MP3000
RAM and EEPROM in the SERVOPACK
* indicates the data that is written.
7.4.5
When Saving Data to Flash Memory
When data is saved to flash memory, the MP3000 writes the settings of the parameters that are
stored in SDRAM to flash memory.
* indicates the data that is written.
Note: Always save all of the SERVOPACK parameter settings to the flash memory after any changes are made.
Flash
memory
SDRAM
SRAM
SERVOPACK
parameters
for all axes
Parameters
System
software
EEP
-ROM
RAM
Control
software
MECHATROLINK
SERVOPACK SERVOPACK
Transferred. Transferred.
MPE720 (Online)
***
MP3000
Flash
memory
SDRAM
SRAM
SERVOPACK parameters
for all axes
Parameters
System
software
EEP
-ROM
RAM
Control
software
MECHATROLINK
SERVOPACK SERVOPACK
Transferred. Transferred.
MP3000
MPE720 (Online)
*