2.5 MECHATROLINK Transmission Cycle and the Number of Connected Slave Stations
2-17
2
Basic Information on Motion Control Function Modules
2.5
MECHATROLINK Transmission Cycle and the Number of Connected Slave Stations
The relationship between the MECHATROLINK transmission cycle and the number of con-
nected slave stations when the SVC Function Module is used is given in the following tables.
Cascade Connections
*1. Up to 16 Servo Drive stations can be connected.
*2. Up to 32 Servo Drive stations can be connected.
Star Connections
*1. Up to 16 Servo Drive stations can be connected.
*2. Up to 32 Servo Drive stations can be connected.
Transmission Cycle
Number of Connected
Stations
Connection Conditions
SVC SVC32
125 μs 1 to 3 1 to 3
250 μs 1 to 7 1 to 7
500 μs 1 to 12 1 to 12
1 ms
1 to 21
*1
1 to 21
If more than 17 stations are connected, two ports must be
used.
1.5 ms 1 to 27
If more than 19 stations are connected, two ports must be
used.
No more than 19 stations can be connected to a single
port.
2 ms 1 to 32
If more than 19 stations are connected, two ports must be
used.
No more than 19 stations can be connected to a single
port.
3 ms
1 to 38
*2
If more than 19 stations are connected, two ports must be
used.
No more than 19 stations can be connected to a single
port.
Transmission Cycle
Number of Connected Stations
SVC SVC32
125 μs 1 to 4 1 to 4
250 μs 1 to 8 1 to 8
500 μs 1 to 14 1 to 14
1 ms
1 to 21
*1
1 to 29
1.5 ms
1 to 42
*2
2 ms
1 to 42
*2
3 ms
1 to 42
*2