EasyManua.ls Logo

YASKAWA SVC - Deleting Unused Motion Control Function Modules

YASKAWA SVC
623 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7.1 Module Configuration Settings
7.1.2 Deleting Unused Motion Control Function Modules
7
Making Settings for Motion Control with the MPE720
7-5
Hexadecimal Code
The hexadecimal code displayed in the Status Column is described below.
7.1.2
Deleting Unused Motion Control Function Modules
You can delete (disable) unused Motion Control Function Modules to reduce the processing
time of the MP3000.
Use the following procedure to delete unused Function Modules from the Motion Control Func-
tion Modules that are built into the MP3000.
1.
Right-click the cell of the Function Module to delete and select Device Select from the
pop-up menu.
The Function Module Dialog Box is displayed.
FEDCBA9876543 210
Normal transmission
Reserved
Reserved
Model code (01 hex: Inverter, 02 hex: Servo or Stepping Motor Drive,
03 hex: I/O)
Low-speed scan transmission error
Duplicate Address
High-speed scan transmission error

Table of Contents

Related product manuals