11.3 MECHATROLINK-III I/O Module Settings
11.3.1 Link Assignment Tab Page Settings
11-13
11.3
MECHATROLINK-III I/O Module Settings
This section describes the settings for MECHATROLINK-III I/O Modules.
11.3.1
Link Assignment Tab Page Settings
When connecting a MECHATROLINK-III I/O Module, set up the slave device on the Link
Assignment Tab Page as given in the following table and save those settings.
You must use IOWin to set the parameters of the I/O Modules with MECHATROLINK-III Commu-
nications (JEPMC-MTA2900-E, JEPMC-MTA2910-E, JEPMC-MTP2900-E, and
JEPMC-MTP2910-E).
Refer to the following manual for details.
MECHATROLINK-III Compatible I/O Module User’s Manual (Manual No.: SIEP C880781 04)
: Can be set.
VENDOR DEVICE PROFILE BYTE
SIZE
SCAN
INPUT OUTPUT
Yaskawa Electric
co.
JAPMC-MC2320-E
Standard
I/O
16, 32, 48,
64
8, 16, 24, 32 8, 16, 24, 32
SVC32
16, 32, 48,
64
8, 16, 24, 32 8, 16, 24, 32
JEPMC-MTD2310-E 16 8 8
JEPMC-MTA2900-E 32 16 16
JEPMC-MTA2910-E 16 8 8
JEPMC-MTP2900-E 64 32 32
JEPMC-MTP2910-E 64 32 32