2.4 Topologies
2.4.1 Cascade Connections
2-14
2.4
Topologies
The SVC Function Module uses MECHATROLINK-III communications to control slave devices.
You can connect the MP3000 and MECHATROLINK-III slave devices with cascade, star, or
mixed cascade/star topologies. This section describes these topologies.
2.4.1
Cascade Connections
Cascade connections allow you to connect one or more series of slave stations from the
MECHATROLINK-III communications port (CN6) on the MP3000.
Note: This connection example uses a transmission cycle of 3 ms.
Figure 2.1 Cascade Connections Using Only One Port
Note: This connection example uses a transmission cycle of 3 ms.
Figure 2.2 Cascade Connections Using Two Ports
CPU Unit
No terminating resistor is required.
Up to 19 slave stations (Machine Controllers, servos, or I/O)
CPU Unit
No terminating
resistor is required.
Up to 38 stations, including Machine Controllers and I/O
Up to 32 Servo stations
No terminating
resistor is
required.