10.2 Setup Procedure
10.2.2 Inverter Settings
10-4
10.2.2
Inverter Settings
Use the following flowchart to make the Inverter settings.
The procedures for STEP 1 to STEP 5 are given below.
STEP 1: Define the Module Configuration of the Inverter
You can define the Module configuration of the Inverter either automatically or manually.
Automatic Definition Method
1.
Execute self configuration on the MP3000.
When you execute self configuration, information on the Modules that are connected to the MP3000
is detected and the Inverter I/O registers are assigned in the SVC definition file. Refer to the following
manual for the procedure to execute self configuration.
MP3000 Series Machine Controller Setup Manual (Manual No.: SIEP C880725 00)
2.
Open the Module Configuration Tab Page. Refer to step 2 in
Manual Definition
Method for the procedure.
3.
Confirm that communications have been established. Refer to steps 8 to 12 in the
Manual Definition Method for the procedure.
This concludes the procedure.
Manual Definition Method
1.
Start the MPE720 on a computer that is connected to the MP3000.
2.
In the Main Window of the MPE720, click Setup - Module configuration from the
Launcher, or the Module Configuration Icon on the My Tool View of the Start Tab Page.
The Module Configuration Definition Tab Page will be displayed.
STEP 1: Define the Module Configuration of the Inverter
STEP 2: Set the Required Fixed Parameters
STEP 3: Confirm That the Inverter Is Ready for Operation
STEP 4: Execute the Inverter Operation Control Command
STEP 5: Set the Required Setting Parameters