7.4 SERVOPACK Parameter Data Flow
7.4.2 Normal Operation
7-24
7.4.2
Normal Operation
The flow of data for the SERVOPACK parameters under normal operation is shown below.
1.
The SERVOPACK’s control software operates according to the parameters that are
stored in RAM.
2.
Some setting parameters and commands of the MP3000 temporarily change SERVO-
PACK parameters. When this processing is executed, it also changes the contents of
the RAM in the SERVOPACK.
Chapter 3 Parameters for Motion Control
* indicates the data that is written.
7.4.3
When the SERVOPACK Tab Page Is Opened
The flow of data for the SERVOPACK parameters when the SERVOPACK Tab Page is opened
is shown below.
Refer to the following section for the procedure to display the SERVOPACK Tab Page.
7.3.1 Displaying and Setting Motion Parameters on page 7-19
The MPE720 loads the parameter values in the SERVOPACK’s RAM and displays them on the
SERVOPACK Tab Page.
A Digital Operator that is connected to the SERVOPACK will display the parameters that are
stored in the SERVOPACKs RAM. Press the DATA/ENTER Key to write the parameters to
the EEPROM.
SDRAM
SRAM
Parameters
EEP
-ROM
RAM
MECHATROLINK
MPE720
*
Hard disk drive of the PC
Settings
Temporarily
changed.
Transferred.Transferred.
SERVOPACKSERVOPACK
MP3000
Control
software
System
software
SERVOPACK
parameters
for all axes
Flash
memory
Information
SDRAM
SRAM
Parameters
EEP
-ROM
RAM
MECHATROLINK
MPE720 (Online)
MP3000
Transferred.Transferred.
SERVOPACKSERVOPACK
Control
software
System
software
SERVOPACK
parameters
for all axes
Flash
memory

Table of Contents