2.5 MECHATROLINK Transmission Cycle and the Number of Connected Slave Stations
2.4.3 Mixed Cascade/Star Connections
2-18
Mixed Cascade/Star Connections
*1. Up to 16 Servo Drive stations can be connected.
*2. Up to 32 Servo Drive stations can be connected.
Note: The above connection conditions assume that the following conditions are met: Number of transmission
bytes: 48, Distance between stations: 100 m., Number of retries: 1.
Transmission
Cycle
Number of Connected Stations
Connection Conditions
SVC SVC32
125 μs 1 to 4 1 to 4 Only star connections can be used.
250 μs 1 to 8 1 to 8
A single cascade connection series must con-
sist of no more than 2 stations.
500 μs 1 to 14 1 to 14
A single cascade connection series must con-
sist of no more than 6 stations.
1 ms
1 to 21
*1
1 to 29
A single cascade connection series must con-
sist of no more than 7 stations.
1.5 ms
1 to 42
*2
A single cascade connection series must con-
sist of no more than 8 stations.
2 ms
1 to 42
*2
A single cascade connection series must con-
sist of no more than 16 stations.
3 ms
1 to 42
*2
A single cascade connection series must con-
sist of no more than 18 stations.
If the SigmaWin+ is connected through the MP3000, the SigmaWin+ may not be usable if there
are too many SERVOPACK stations connected.
If this occurs, either connect the SigmaWin+ to the SERVOPACK (CN7) directly, or lengthen the
transmission cycle.