3.4 Motion Parameter Details
3.4.2 Setting Parameter Details
3-51
3
Parameters for Motion Control
Setting Precautions
When Set to 0
When bit 0 in the IW0C monitor parameter (Distribution Completed) changes to 1
(Completed), bit 3 in the IW0C changes to 1.
When Not Set to 0
Bit 3 in the IW0C changes to 1 in the following case, regardless of the status of the Dis-
tribution Completed Flag.
|(IL12) (IL16)| OL20
IL12: Machine Coordinate System Reference Position (MPOS)
IL16: Machine Coordinate System Feedback Position (APOS)
OL20: NEAR Signal Output Width
This parameter has no relation to the NEAR Signal Width parameter in the SERVOPACK.
Related Parameters
IW0C monitor parameter, bit 3 (Near Position)
Excessive Deviation Detection Value
Excessive Deviation Detection Value
Set the value to detect an excessive deviation during position control.
Setting Precautions
Bit 9 in the IL04 monitor parameter (Excessive Deviation) changes to 1 (Excessive devia-
tion) in the following case.
|Position Deviation (IL1A)| > Excessive Deviation Detection Value
Excessive deviation is not detected when this parameter is set to 0.
Related Parameters
Bit 0 in the OW01 setting parameter (Excessive Deviation Error Level Setting) can be set
to treat excessive deviation errors as either warnings or alarms.
Bit 0 in OW01 = 0: Treat as an alarm (default). Axis operation stops.
Bit 0 in OW01 = 1: Treat as a warning. Axis operation continues.
Positioning Completion Check Time
Positioning Completion Check Time
Set the time to detect a Positioning Time Exceeded error.
Register
Address
Name
Setting
Range
Setting Unit Default Control mode
OL22
Excessive Deviation Detection
Value
0 to 2
31
1
Reference
units
2
31
1
Register
Address
Name
Setting
Range
Setting Unit Default Control mode
OW26
Positioning Completion Check
Time
0 to 65,535 ms 0
SVC
Position
Phase
SVC
Position
Phase