3.4  Motion Parameter Details
 3.4.2  Setting Parameter Details
3-67
3
Parameters for Motion Control
• If an axis attempts to move in the forward direction past this position, a positive software limit 
alarm occurs and bit 3 in the IL04 monitor parameter changes to 1.
• The software limit is enabled only after bit 5 (Zero Point Return/Setting Completed) in the 
IW0C monitor parameter changes to 1 (Completed). Refer to the following section for 
details.
Refer to the following section for details.
6.3 Software Limits on page 6-9
 Negative Software Limit
Set the position to detect the software limit in the reverse direction for the MP3000.
Setting Precautions
• This parameter is valid when bit 2 (Enable Negative Software Limit) in fixed parameter No. 1 is 
set to 1 (Enabled) and bit C (Software Limit Parameter Selection) is set to 1 (Setting parame-
ter).
• If an axis attempts to move in the reverse direction past this position, a negative software limit 
alarm occurs and bit 4 in the IL04 monitor parameter changes to 1.
• The software limit is enabled only after bit 5 (Zero Point Return/Setting Completed) in the 
IW0C monitor parameter changes to 1 (Completed). Refer to the following section for 
details.
Refer to the following section for details.
6.3 Software Limits on page 6-9
SERVOPACK Parameters
 User-specified SERVOPACK Parameter Set Value
Set the data to automatically apply to the SERVOPACK parameter specified by fixed parameter 
No. 44 (User-specified SERVOPACK Parameter Number).
SERVOPACK Transmission Reference Mode
 Command Buffers for SERVOPACK Transmission Reference 
Mode
These parameters are used for command data when MECHATROLINK Servo commands are 
specified directly.
These parameters are used in SERVOPACK Transmission Reference Mode only. Set fixed 
parameter No. 0 (Operation Mode Selection) to 3 (SERVOPACK Transmission Reference 
Mode).
Refer to the following section for details.
3.4.1 Fixed Parameter Details on page 3-27 − 
 Operation Mode Selection on page 3-27
Register 
Address
Name
Setting 
Range
Setting Unit Default Control mode
OL68 Negative Software Limit
-2
31
 to 2
31
−1
Reference 
units
-2
31
Register 
Address
Name
Setting 
Range
Setting Unit Default Control mode
OL70
User-specified SERVOPACK 
Parameter Set Value
-2
31
 to 2
31
−1
− 0 −
Register 
Address
Name
Setting 
Range
Setting Unit Default Control mode
OW68 
to 
OW7F
Command Buffers for SERVO-
PACK Transmission Reference 
Mode
−−0 −
Position
Speed
Phase
Torqu e
SVC
SVC