3.4 Motion Parameter Details
3.4.3 Monitor Parameter Details
3-79
3
Parameters for Motion Control
Precautions
• This parameter changes to 0 when the ZRET (Zero Point Return) motion command is exe-
cuted.
• The range for this parameter is 0 to (infinite-length axis reset position
−
1) when bit 0 (Axis
Selection) in fixed parameter No. 1 is set to 1 (Infinite-length axis).
Machine Coordinate System Latch Position (LPOS)
This parameter reports the latch position when the latch is completed.
Position Deviation (PERR)
This parameter reports the following deviation (internal Servo reference position − feedback
position, converted to reference units) managed by the SVC Function Module.
Target Position Increment Monitor (PDV)
This parameter reports the distribution amount for each scan.
Number of POSMAX Turns
The count stored in this parameter goes up or down each time the current position exceeds the
set value of fixed parameter No. 10 (Infinite-length Axis Reset Position).
Precautions
• This parameter is valid for infinite-length axes.
• This parameter is not valid for linear motors.
Reference Monitors
Speed Reference Output Monitor
This parameter reports the speed reference value that is currently being output. This parameter
monitors the speed that is output to the servo.
Precautions
This parameter is 0 for interpolation or phase control.
Register
Address
Name Range Unit
IL18 Machine Coordinate System Latch Position (LPOS)
-2
31
to 2
31
−1
Reference units
Register
Address
Name Range Unit
IL1A Position Deviation (PERR)
-2
31
to 2
31
−1
Reference units
Register
Address
Name Range Unit
IL1C Target Position Increment Monitor (PDV)
-2
31
to 2
31
−1
Reference units
Register
Address
Name Range Unit
IL1E Number of POSMAX Turns
-2
31
to 2
31
−1
turn
Machine Coordinate System
This is the basic coordinate system that is set based on the execution of the ZRET (Zero Point
Return) or ZSET (Set Zero Point) command. The MP3000 manages positions using this machine
coordinate system.
Register
Address
Name Range Unit
IL20 Speed Reference Output Monitor
-2
31
to 2
31
−1
pulse/s
SVR
SVR