Maintenance and Inspection Precautions
The Move on Machine Coordinates (MVM) instruction temporarily performs positioning to a
coordinate position in the machine coordinate system. Therefore, unexpected operation may
occur if the instruction is executed without confirming the origin position in the machine coordi-
nate system first. When you use the MVM instruction, always confirm that the machine origin is
in the correct position before you begin operation.
There is a risk of injury or device damage.
NOTICE
When you adjust the gain during system commissioning, use a measuring instrument to monitor
the torque waveform and speed waveform and confirm that there is no vibration.
If a high gain causes vibration, the Servomotor will be damaged quickly.
Do not frequently turn the power supply ON and OFF. After you have started normal operation,
allow at least one hour between turning the power supply ON and OFF (as a guideline).
Do not use the SERVOPACK in applications that require the power supply to be turned ON and
OFF frequently.
The elements in the SERVOPACK will deteriorate quickly.
An alarm or warning may occur if axis movement instructions are executed from the MP3000
during MPE720 or SigmaWin+ operation.
If an alarm or warning occurs, it may interrupt the current process and stop the system.
After you complete trial operation of the machine and facilities, use the MPE720 or the Sig-
maWin+ to create a backup file of the SERVOPACK parameters. You can use them to reset the
parameters after SERVOPACK replacement.
If you do not copy backed up parameter settings, normal operation may not be possible after a
faulty SERVOPACK is replaced, which could result in machine or equipment damage.
DANGER
Do not change any wiring while power is being supplied.
There is a risk of electric shock or injury.
WARNING
Wiring and inspections must be performed only by qualified engineers.
There is a risk of electric shock or SERVOPACK failure.
CAUTION
Wait for at least six minutes after turning OFF the power supply and then make sure that the
CHARGE indicator is not lit before starting wiring or inspection work. Do not touch the power
supply terminals while the CHARGE lamp is lit because high voltage may still remain in the SER-
VOPACK even after turning OFF the power supply.
There is a risk of electric shock.
Before you replace a SERVOPACK, back up the settings of the SERVOPACK parameters. Copy
the backed up parameter settings to the new SERVOPACK and confirm that they were copied
correctly.
If you do not copy backed up parameter settings or if the copy operation is not completed correctly,
normal operation may not be possible, possibly resulting in machine or equipment damage.
Do not attempt to disassemble or repair the SERVOPACK.
There is a risk of electric shock, injury, or device damage.