4.2  Motion Command Details
 4.2.12  CHG_FILTER (Change Filter Type)
4
Motion Control Program Commands and Instructions
4-69
 Monitor Parameters
Timing Charts
 Normal Completion
 Error Completion
Register 
Address
Name Monitored Contents
IL
02 Warnings This parameter reports the current warning status.
IL04 Alarms This parameter reports the current alarm status.
IW
08
Motion Command 
Response Code
This parameter shows the motion command currently in execution.
This parameter is 13 during execution of the CHG_FILTER command.
IW09 
Bit 0
Command Execu-
tion Flag
This bit is 1 (Processing) during execution of the CHG_FILTER com-
mand. The bit changes to 0 (Completed) when execution ends.
IW
09 
Bit 1
Command Hold 
Completed
This bit is always 0 (Command hold not completed) for the CHG_FIL-
TER command.
IW
09 
Bit 3
Command Error End
This bit changes to 1 (Completed with an error) when an error occurs 
during execution of the CHG_FILTER command.
The axis will decelerate to a stop if it is moving. This bit changes to 0 
(Completed normally) when another command is executed.
IW09 
Bit 8
Command Execu-
tion Completed
This bit changes to 1 (Normal execution completed) when execution of 
the CHG_FILTER command ends.
OW08 = 13 (CHG_FILTER)
IW08 = 13 (CHG_FILTER)
IW09 Bit 0 (BUSY)
IW09 Bit 8 (COMPLETE)
IW09 Bit 3 (FAIL)
1 scan
OW08 = 13 (CHG_FILTER)
IW08 = 13 (CHG_FILTER)
IW09 Bit 0 (BUSY)
IW09 Bit 8 (COMPLETE)
IW09 Bit 3 (FAIL)