4.2 Motion Command Details
4.2.19 ALM_HIST (Monitor Alarm History)
4
Motion Control Program Commands and Instructions
4-83
Monitor Parameters
Timing Charts
Normal Completion
Error Completion
Register
Address
Name Monitored Contents
IL
02 Warnings This parameter reports the current warning status.
IL04 Alarms This parameter reports the current alarm status.
IW
08
Motion Command
Response Code
This parameter shows the motion command currently in execution.
This parameter is 20 during execution of the ALM_HIST command.
IW09
Bit 0
Command Execu-
tion Flag
This bit changes to 1 (Processing) during execution of the ALM_HIST
command. The bit changes to 0 (Completed) when execution ends.
IW
09
Bit 1
Command Hold
Completed
This bit is always 0 (Command hold not completed) for the ALM_HIST
command.
IW
09
Bit 3
Command Error End
This bit changes to 1 (Completed with an error) when an error occurs
during execution of the ALM_HIST command.
The axis will decelerate to a stop if it is moving. This bit changes to 0
(Completed normally) when another command is executed.
IW09
Bit 8
Command Execu-
tion Completed
This bit changes to 1 (Normal execution completed) when operation of
the ALM_HIST command ends.
IW
2D
SERVOPACK Alarm
Code
This parameter stores the SERVOPACK alarm code that was read.
OW08 = 20 (ALM_HIST)
IW08 = 20 (ALM_HIST)
IW09 Bit 0 (BUSY)
IW09 Bit 8 (COMPLETE)
IW09 Bit 3 (FAIL)
IL38
This interval is
not constant.
Undened value
Read results
OW08 = 20 (ALM_HIST)
IW08 = 20 (ALM_HIST)
IW09 Bit 0 (BUSY)
IW09 Bit 8 (COMPLETE)
IW09 Bit 3 (FAIL)
IL38
This interval is
not constant.
Undened value