EasyManua.ls Logo

YASKAWA SVC - Page 261

YASKAWA SVC
623 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4.2 Motion Command Details
4.2.30 PMEM_RD (Read Non-volatile Memory)
4-118
Monitor Parameters
Timing Charts
Normal Completion
Error Completion
Register
Address
Name Monitored Contents
IL
02 Warnings This parameter reports the current warning status.
IL04 Alarms This parameter reports the current alarm status.
IW
08
Motion Command
Response Code
This parameter shows the motion command currently in execution.
This parameter is 37 during execution of the PMEM_RD command.
IW09
Bit 0
Command Execu-
tion Flag
This bit is 1 (Processing) during execution of the PMEM_RD command.
The bit changes to 0 (Completed) when execution ends.
IW
09
Bit 1
Command Hold
Completed
This bit is always 0 (Command hold not completed) for the PMEM_RD
command.
IW
09
Bit 3
Command Error End
This bit changes to 1 (Completed with an error) when an error occurs
during execution of the PMEM_RD command.
The axis will decelerate to a stop if it is moving. This bit changes to 0
(Completed normally) when another command is executed.
IW09
Bit 8
Command Execu-
tion Completed
This bit changes to 1 (Normal execution completed) when execution of
the PMEM_RD command ends.
IL38
SERVOPACK
Parameter Read
Data
This parameter stores the data read from the specified address.
OW08 = 37 (PMEM_RD)
IW08 = 37 (PMEM_RD)
IW09 Bit 0 (BUSY)
IW09 Bit 8 (COMPLETE)
IL38
IW09 Bit 3 (FAIL)
This interval is
not constant.
Undened value
Read results
OW08 = 37 (PMEM_RD)
IW08 = 37 (PMEM_RD)
IW09 Bit 0 (BUSY)
IW09 Bit 8 (COMPLETE)
IW09 Bit 3 (FAIL)
IL38
This interval is
not constant.
Undened value

Table of Contents