6.6 Slave CPU Synchronization
6.6.3 Setting Procedure
6-23
6
Other Useful Functions
5.
Select Enable from the Slave synchronous function Box.
Note: You cannot enable this function on a sub CPU.
6.
Click the Link Assignment Ta b.
7.
Make the following settings.
No. Item Description
ADR Station address (fixed)
ExADR 0
VENDOR Yaskawa Electric co.
DEVICE SVC32
PROFILE Standard I/O
BYTE 16, 32, 48, or 64 (Set the same value as you set for the master station.)
D Not selected (I/O enabled).
INPUT First register address in input area
SIZE 8, 16, 24, or 32 (Set the same value as you set for the master station.)
OUTPUT First register address in output area
SCAN High (fixed)
