3.4 Motion Parameter Details
3.4.1 Fixed Parameter Details
3-33
3
Parameters for Motion Control
Negative Software Limit
Set the position to detect the software limit in the reverse direction for the MP3000.
Setting Precautions
If an axis attempts to move in the reverse direction past this position, a negative software limit
alarm occurs and bit 4 in the IL04 monitor parameter changes to 1.
This parameter is valid when bit 2 (Enable Negative Software Limit) in fixed parameter No. 1 is
set to 1 (Enabled).
The software limit is enabled only after bit 5 (Zero Point Return/Setting Completed) in the
IW0C monitor parameter changes to 1 (Completed). Refer to the following section for
details.
6.3 Software Limits on page 6-9
SERVOPACK Settings
Motor Type Selection
Select the motor type to use.
0: Rotary motor
1: Linear motor
Encoder Selection
Set the encoder type to use.
0: Incremental encoder.
1: Absolute encoder.
2: Absolute encoder used as incremental encoder.
3: Reserved.
Setting Precautions
For linear motors, set the encoder type that matches the linear scale and SERVOPACK set-
tings.
No. Name Setting Range Setting Unit Default
14 Negative Software Limit
-2
31
to 2
31
1
Reference units
-2
31
No. Name Setting Range Setting Unit Default
29 Motor Type Selection 0, 1 0
No. Name Setting Range Setting Unit Default
30 Encoder Selection 0 to 2 0
SVC
SVC
SVC