148 Program features
Settings
Diagnostics
1. Parameters 2. Additional information
82.01 SMART SLOWDN SEL Enables/disables the Smart slowdown function.
82.02 LV STOP SWC DIST Defines the distance between leveling and stop switches.
82.03 SAFETY MARGIN Defines what percentage of parameter 82.02 is used as the safety
distance.
3. Signals 4. Additional information
Actual signals
01.10 POS ACT Actual position of the encoder.
05.06 LVLING DIST ACT Displays the actual leveling distance.
05.07 FLOOR DISTANCE Displays the distance between two floors.
Alarms
SMART SLOWDOWN CONFIG Smart slowdown function is enabled with an encoder, but
encoder/resolver feedback is not configured.