220 Parameters
12.08 DI INVERT MASK
Inverts status of digital inputs as reported by 02.01 DI
STATUS. For example, a value of 0b000100 inverts
the status of DI3 in the signal.
0b000000/
UINT32
0b000000…
0b111111
DI status inversion mask. 1 = 1 / -
12.09 DIO INVERT MASK
Inverts status of digital inputs/outputs DIO1…3 as
reported by 02.03 DIO STATUS.
For example, a value of 0b001 inverts the status of
DIO1 in the signal.
0b000/
UINT32
0b000…0b111 DIO status inversion mask. 1 = 1 / -
12.80 EXT IO SEL Activates an I/O extension installed into Slot 2.
None/
enum
None No extension installed into Slot 2. 0
FIO-01 FIO-01 extension installed into Slot 2. 1
12.81 EXT IO DIO1 CONF Selects whether extension DIO1 is used as a digital input or
as a digital output in a FIO-01 digital I/O extension module.
Input/
enum
Input Extension DIO1 is used as a digital input. 0
Output Extension DIO1 is used as a digital output. 1
No. Bit/Name/Value/
Range
Description Def/Type
FbEq
(16b/32b)
Bit Name Value Information
0 INVERT DI1 1 Digital input DI1 is Off
0 Digital input DI1 is On.
1 INVERT DI2 1 Digital input DI2 is Off
0 Digital input DI2 is On.
2 INVERT DI3 1 Digital input DI3 is Off
0 Digital input DI3 is On.
3 INVERT DI4 1 Digital input DI4 is Off.
0 Digital input DI4 is On.
4 INVERT DI5 1 Digital input DI5 is Off.
0 Digital input DI5 is On.
5 INVERT DI6 1 Digital input DI6 is Off.
0 Digital input DI6 is On.
Bit Name Value Information
0 INVERT DIO1 1 Digital input/output DIO1 is Off
0 Digital input/output DiO1 is On.
1 INVERT DIO2 1 Digital input/output DIO2 is Off.
0 Digital input/output DIO2 is On.
2 INVERT DIO3 1 Digital input/output DIO3 is Off.
0 Digital input/output DIO3 is On.

Table of Contents