Parameters 263
80.02 GEAR RATIO
Defines the gear box ratio used in m/s to rpm
conversions and vice versa.
1.000 /
Real
0.001…1000.000
Gear box ratio. 1000 = 1
80.03 SHEAVE
DIAMETER
Defines the sheave diameter of the lift system 500 mm
1…2000 mm
Sheave diameter in millimeters. 1 = 1 mm
80.04 ROPING RATIO
Defines the roping ratio of the lift system. 1/ Real
1…8
System roping ratio. 1 = 1
80.05 SPEED REF MODE
Selects the speed reference mode. See also section
Speed reference selection and scaling on page 137.
MULTIPLE/
enum
MULTIPLE
Used for multiple speed references.
Up to eight separate preset speed references can be
programmed to the drive using parameters in this
group and can be selected using binary coded digital
inputs.
0
SEP HIGH PRI
Used when high speed reference has priority.
Up to seven different speeds can be programmed to
the drive and can be selected using dedicated digital
inputs. Each speed reference takes priority over the
leveling speed.
1
SEP LEVL PRI
Used when leveling speed reference has priority.
Up to seven different speeds can be programmed to
the drive and can be selected using dedicated digital
inputs. The leveling speed reference, takes priority
over all other speed references when enabled
through one of the digital input terminals.
2
80.06 SPEED REF SEL1
Selects the source for speed reference selection
pointer 1. The bit combination of parameters 80.06,
80.07, 80.08 and 80.09 determines the speed
reference when neither the evacuation mode nor the
inspection mode is active.
DI4/
Bit pointer
Bit pointer: CONST or POINTER (See Terms and
abbreviations on page 183.)
80.07 SPEED REF SEL2
Selects the source for speed reference selection
pointer 2. The bit combination of parameters 80.06,
80.07, 80.08 and 80.09 determines the speed
reference when neither the evacuation mode nor the
inspection mode is active.
DI5/
Bit pointer
Bit pointer: CONST or POINTER (See Terms and
abbreviations on page 183.)
No. Bit/Name/Value/
Range
Description Def/Type