EasyManua.ls Logo

ABB ACL30 - Page 264

ABB ACL30
360 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
264 Parameters
80.08 SPEED REF SEL3
Selects the source for speed reference selection
pointer 3. The bit combination of parameters 80.06,
80.07, 80.08 and 80.09 determines the speed
reference when neither the evacuation mode nor the
inspection mode is active.
DI6/
Bit pointer
Bit pointer: CONST or POINTER (See Terms and
abbreviations on page 183.)
80.09 SPEED REF SEL4
Selects the source for speed reference selection
pointer 4. The bit combination of parameters 80.06,
80.07, 80.08 and 80.09 determines the speed
reference when neither the evacuation mode nor the
inspection mode is active.
NOT USED/
Bit pointer
Bit pointer: CONST or POINTER (See Terms and
abbreviations on page 183.)
80.10 SPEED1
A factory-set zero speed reference (0 m/s) to be
used when the bit combination of parameters 80.06,
80.07 and 80.08 is 000. Can be used for stopping the
lift in the normal travel mode. Cannot be set by the
user.
This parameter is read-only.
0.00 m/s /
Real
0.00...25.00 m/s
Speed reference 100 = 1 m/s
80.11 LEVELING SPEED
Defines the speed reference to be used during
leveling, ie, when the bit combination of parameters
80.06, 80.07 and 80.08 is 110. When the floor switch
is hit, the drive decelerates to the leveling speed.
0.25 m/s /
Real
0.00…25.00 m/s
Leveling speed reference. 100 = 1 m/s
80.12 RELVL SPEED SEL
Selects the source of the speed reference to be used
in the releveling mode. If the lift overshoots the floor
level, it is driven back to the floor level using the
releveling mode.
PAR 80.13 /
enum
PAR 80.13 Parameter 80.13 RELEVELING SPEED selected as
the source of the releveling speed reference.
0
AI1 SCALED AI1 signal (02.05 AI1 SCALED) selected as the
source of the releveling speed reference.
1
AI2 SCALED AI2 signal (02.07 AI2 SCALED) selected as the
source of the releveling speed reference.
2
80.13 RELEVELING
SPEED
Defines the speed reference to be used in the
releveling mode when selected as the source of
parameter 80.12 RELVL SPEED SEL. Used when
the bit combination of parameters 80.06, 80.07 and
80.08 is 001.
0.10 m/s /
Real
0.00…25.00 m/s Releveling speed reference. 100 = 1 m/s
No. Bit/Name/Value/
Range
Description Def/Type
FbEq
(16b/32b)

Table of Contents