280 Parameters
93.09 EMUL POS
OFFSET
Defines the zero point for emulated position in
relation of the zero point of the input position (within
one revolution). The input position is selected by
parameter 90.02 EMUL MODE SEL.
For example, if the offset is 0, an emulated zero
pulse is generated each time the input position
moves across 0. With an offset of 0.5, an emulated
zero pulse is generated each time the input position
(within one revolution) moves across 0.5.
0.00000 rev
/ Real
0.00000
…0.99998 rev
Emulated zero pulse position offset.
- / 100000 =
1rev
97
97 USER MOTOR
PAR
User adjustment of motor model values estimated
during ID run. The values can be entered in either
“per unit” or SI.
97.01 USE GIVEN
PARAMS
Activates the motor model parameters 97.0297.14
and the rotor angle offset parameter 97.17.
Notes:
The parameter value is automatically set to zero
when ID run is selected by parameter 99.10
IDRUN MODE. The values of parameters
97.0297.14 are updated according to the motor
characteristics identified during the ID run.
This parameter cannot be changed while the drive
is running.
NoUserPars
/ enum
NoUserPars Parameters 97.0297.14 inactive. 0
UserMotPars The values of parameters 97.0297.14 are used in
the motor model.
1
UserPosOffs The value of parameter 97.17 is used as the rotor
angle offset. Parameters 97.0297.14 are inactive.
2
AllUserPars The values of parameters 97.0297.14 are used in
the motor model, and the value of parameter 97.17 is
used as the rotor angle offset.
3
97.02 RS USER
Defines the stator resistance R
S
of the motor model. 0.00000 p.u.
/ Real24
0.00000…
0.50000 p.u
Stator resistance. - / 100000 =
1 p.u
97.03 RR USER
Defines the rotor resistance R
R
of the motor model.
Note: This parameter is valid only for asynchronous
motors.
0.00000 p.u.
/ Real24
0.00000…
0.50000 p.u
Rotor resistance. - / 100000 =
1 p.u
No. Bit/Name/Value/
Range
Description Def/Type
FbEq
(16b/32b)

Table of Contents