A96G166/A96A166/A96S166 User’s manual 18. Reset
181
LVICR (Low Voltage Indicator Control Register): 86H
7
6
5
4
3
2
1
0
–
–
LVIF
LVIEN
LVILS3
LVILS2
LVILS1
LVILS0
–
–
R/W
R/W
R/W
R/W
R/W
R/W
Initial value: 00H
LVIF
Low Voltage Indicator Flag Bit
0
No detection
1
Detection
LVIEN
LVI Enable/Disable
0
Disable
1
Enable
LVIVS[3:0]
LVI Level Select
LVIVS3
LVIVS2
LVIVS1
LVIVS0
Description
0
0
0
0
Not available
0
0
0
1
Not available
0
0
1
0
Not available
0
0
1
1
1.88V
0
1
0
0
2.00V
0
1
0
1
2.13V
0
1
1
0
2.28V
0
1
1
1
2.46V
1
0
0
0
2.68V
1
0
0
1
2.81V
1
0
1
0
3.06V
1
0
1
1
3.21V
1
1
0
0
3.55V
1
1
0
1
3.73V
1
1
1
0
3.91V
1
1
1
1
4.25V