EasyManua.ls Logo

Abov A96G166 - Low Voltage Reset and Low Voltage Indicator Characteristics; Table 49. LVR and LVI Characteristics

Default Icon
247 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
20. Electrical characteristics A96G166/A96A166/A96S166 User’s manual
204
20.6 Low voltage reset and low voltage indicator characteristics
Table 49. LVR and LVI Characteristics
(T
A
=-40°C ~ +85°C or T
A
=-40°C ~ 105°C, VDD=1.8V ~ 5.5V, VSS=0V)
Parameter
Symbol
Conditions
MIN
TYP
MAX
Unit
Detection level
V
LVR
V
LVI
The LVR can select all levels.
But LVI can select other levels except
1.61/1.68/1.77V because the minimum
operating voltage is 1.8V.
V
LVR
/V
LVI
can be measured when
voltage drops (falling level).
-
1.61
1.75
V
1.55
1.68
1.81
1.63
1.77
1.91
1.73
1.88
2.03
1.84
2.00
2.16
1.96
2.13
2.30
2.10
2.28
2.46
2.26
2.46
2.66
2.47
2.68
2.89
2.59
2.81
3.03
2.82
3.06
3.30
2.95
3.21
3.47
3.28
3.56
3.84
3.43
3.73
4.03
3.60
3.91
4.22
3.91
4.25
4.59
Hysteresis
V
30
180
mV
Minimum pulse width
t
LW
100
us
LVR and LVI current
I
BL
Enable (Both)
VDD= 3V,
@RUN Mode
14.0
24.0
uA
Enable (One of two)
10.0
18.0
Disable (Both)
VDD= 3V
0.1
NOTE: Guaranteed by design.

Table of Contents