11.2.2 16-bit capture mode
It uses an internal/external clock as a clock source. Basically, the 16-bit timer 1 capture mode has the
same function as the 16-bit timer/counter mode, and the interrupt occurs when T1CNTH/T1CNTL is
equal to T1ADRH/T1ADRL. The T1CNTH, T1CNTL values are automatically cleared by a match
signal. It can be cleared by software (T1CC) too.
A timer interrupt in capture mode is very useful when the pulse width of captured signal is wider than
the maximum period of timer. Capture result is loaded into T1BDRH/T1BDRL.
According to EIPOL1 registers setting, the external interrupt EINT11 function is selected. EINT11 pin
must be set as an input port.
A Match
T1CC
T1EN
P
r
e
s
c
a
l
e
r
fx
M
U
X
fx/2
fx/4
fx/64
fx/2048
fx/8
fx/1
16-bit Counter
T1CNTH/T1CNTL
16-bit B Data Register
T1BDRH/T1BDRL
Clear
Edge
Detector
T1ECE
EC1
Comparator
16-bit A Data Register
T1ADRH/T1ADRL
T1IFR
INT_ACK
Clear
To interrupt
block
A Match
Buffer Register A
A Match
T1CC
Reload
R
EINT11
T1CNTR
T1EN
3
T1CK[2:0]
Clear
EIPOL1[3:2]
FLAG11
(EIFLAG1.5)
INT_ACK
Clear
To interrupt
block
2
T1MS[1:0]
2
T1EN
T1CRH
1
ADDRESS:BBH
INITIAL VALUE : 0000_0000B
T1BEN T1MS1 T1MS0
– –
T1PE T1CC
X 0 1
– –
X X
T1CK2
T1CRL
X
ADDRESS:BAH
INITIAL VALUE : 0000_0000B
T1CK1 T1CK0 T1IFR T1BPOL T1POL T1ECE T1CNTR
X X X X X X X
T1EN
HSIRC