EasyManua.ls Logo

Abov A96G166 - Internal Flash ROM Characteristics; Input;Output Capacitance; Table 58. Internal Flash Rom Characteristics; Table 59. Input; Output Capacitance

Default Icon
247 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
20. Electrical characteristics A96G166/A96A166/A96S166 User’s manual
214
20.15 Internal flash ROM characteristics
Table 58. Internal Flash Rom Characteristics
(T
A
=-40°C ~ +85°C or T
A
=-40°C ~ 105°C, VDD=1.8V ~ 5.5V, VSS= 0V)
Parameter
Symbol
Condition
MIN
TYP
MAX
Unit
Sector write time
t
FSW
2.5
2.7
ms
Sector erase time
t
FSE
2.5
2.7
Code write protection time
t
FHL
2.5
2.7
Page buffer reset time
t
FBR
5
us
Flash programming frequency
f
PGM
0.4
MHz
Endurance of Write/Erase
NF
WE
30,000
times
NOTE: During a flash operation, SCLK[1:0] of SCCR must be set to 00 or 01 (INT-RC OSC or Main X-TAL for
system clock).
20.16 Input/output capacitance
Table 59. Input / Output Capacitance
(T
A
=-40°C ~ +85°C or T
A
=-40°C ~ 105°C, VDD=0V)
Parameter
Symbol
Condition
MIN
TYP
MAX
Unit
Input Capacitance
C
IN
fx= 1MHz
Unmeasured pins are
connected to VSS
10
Pf
Output Capacitance
C
OUT
I/O Capacitance
C
IO

Table of Contents