EasyManuals Logo

Abov A96G166 User Manual

Default Icon
247 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #80 background imageLoading...
Page #80 background image
9. Watchdog timer A96G166/A96A166/A96S166 User’s manual
80
WDTCR (Watch Dog Timer Control Register): 8DH
7
6
5
4
3
2
1
0
WDTEN
WDTRTI
WDTPDON
WINDOW1
WINDOW0
WDOVF2
WDOVF1
WDOVF0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Initial value: 07H
WDTEN
Control WDT Operation
0
Disable (WDTRC Stop)
1
Enable
WDTRTI
3/4 Interval interrupt
0
Disable (WDT overflow reset used)
1
Watch Dog Timer RESET ON
WDTPDON
Operation on Stop/Idle Mode
0
WDTRC operation stop in Stop/Idle Mode
1
WDTRC operation in Stop/Idle Mode
WINDOW[1:0]
Select WDT window open period
WINDOW1
WINDOW0
Description
0
0
50%
0
1
75%
1
0
100%
1
1
No used
WDOVF[2:0]
Select overflow time
WDOVF2
WDOVF1
WDOVF0
Description
0
0
0
2
6
/f
WDT
0
0
1
2
7
/f
WDT
0
1
0
2
8
/f
WDT
0
1
1
2
9
/f
WDT
1
0
0
2
11
/f
WDT
1
0
1
2
13
/f
WDT
1
1
0
2
14
/f
WDT
1
1
1
2
16
/f
WDT
NOTE: When accessing WDTCR, ‘0x59’ must be first written to
WDTIDR.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Abov A96G166 and is the answer not in the manual?

Abov A96G166 Specifications

General IconGeneral
BrandAbov
ModelA96G166
CategoryComputer Hardware
LanguageEnglish

Related product manuals