9. Watchdog timer A96G166/A96A166/A96S166 User’s manual
80
WDTCR (Watch Dog Timer Control Register): 8DH
7
6
5
4
3
2
1
0
WDTEN
WDTRTI
WDTPDON
WINDOW1
WINDOW0
WDOVF2
WDOVF1
WDOVF0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Initial value: 07H
WDTEN
Control WDT Operation
0
Disable (WDTRC Stop)
1
Enable
WDTRTI
3/4 Interval interrupt
0
Disable (WDT overflow reset used)
1
Watch Dog Timer RESET ON
WDTPDON
Operation on Stop/Idle Mode
0
WDTRC operation stop in Stop/Idle Mode
1
WDTRC operation in Stop/Idle Mode
WINDOW[1:0]
Select WDT window open period
WINDOW1
WINDOW0
Description
0
0
50%
0
1
75%
1
0
100%
1
1
No used
WDOVF[2:0]
Select overflow time
WDOVF2
WDOVF1
WDOVF0
Description
0
0
0
2
6
/f
WDT
0
0
1
2
7
/f
WDT
0
1
0
2
8
/f
WDT
0
1
1
2
9
/f
WDT
1
0
0
2
11
/f
WDT
1
0
1
2
13
/f
WDT
1
1
0
2
14
/f
WDT
1
1
1
2
16
/f
WDT
NOTE: When accessing WDTCR, ‘0x59’ must be first written to
WDTIDR.