220 Firmware Version 6.0
Error Message: “(Row #) mux bus data line short to mux bus ground”.
Possible Cause: Population sensor’s mux bus signal wire is shorted to ground.
Solution: Press OK to dismiss the error. The display then replaces the message window
with an alarm text on the header bar at the top of the Run screen. This alarm text
continues until the wire is fixed or the sensor is disabled. Inspect the wire at the first
opportunity.
Error Message: (Row #) mux bus data line short to mux bus power”.
Possible Cause: Population sensor’s mux bus signal wire is shorted to power wire.
Solution: Press OK to dismiss the error. The display then replaces the message window
with an alarm text on the header bar at the top of the Run screen. This alarm text
continues until the wire is fixed or the sensor is disabled. Inspect the wire at the first
opportunity.
Error Message: “(Row #) communication lost”.
Possible Cause: Seed tube sensor stops communicating with the PMM.
Solution: Press OK to dismiss the error. The display then replaces the message window
with an alarm text on the header bar at the top of the Run screen. This alarm text
continues until the wire is fixed or the sensor is disabled. Inspect the sensor at the first
opportunity.
Error Message: “(Inner or Outer; Right, or Left) Shaft Communication Lost”
Possible Cause: Transmission sensor stops communicating with the PMM.
Solution: Press OK to dismiss the error. The display then replaces the message window
with an alarm text on the header bar at the top of the Run screen. This alarm text
continues until the wire is fixed or the sensor is disabled. Inspect the sensor at the first
opportunity.
Error Message: “(Left or Right) Edge- Vac sensor communication lost”.
Possible Cause: Edge-Vac sensor stops communication with the PMM.
Solution: Press OK to dismiss the error. The display then replaces the message window
with an alarm text on the header bar at the top of the Run screen. This alarm text
continues until the wire is fixed or the sensor is disabled. Inspect the sensor at the first
opportunity.
Error Message: “(Left or Right) SDS shaft sensor communication lost”.
Possible Cause: SDS shaft sensor stops communicating with the PMM.
Solution: Press OK to dismiss the error. The display then replaces the message window
with an alarm text on the header bar at the top of the Run screen. This alarm text
continues until the wire is fixed or the sensor is disabled. Inspect the sensor at the first
opportunity.
Error Message: “Low hydraulic oil level”.
Possible Cause: Hydraulic oil level drops.
Solution: Check oil level on the planter, add as necessary.
Error Message: “High hydraulic oil temperature”
Possible Cause: Hydraulic oil temperature level rises
Solution: Stop planter in order to cool down oil temperature. Inspect for cause of
overheating.
Error Message: “Voltage Error Alarm”.
Possible Cause: Occurs if the battery voltage drops below 10 volts, or rises above 15 volts.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ag Leader Integra Display and is the answer not in the manual?

Ag Leader Integra Display Specifications

General IconGeneral
BrandAg Leader
ModelIntegra Display
CategoryMonitor
LanguageEnglish

Related product manuals