EasyManuals Logo

Ag Leader Integra Display User Manual

Ag Leader Integra Display
376 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #266 background imageLoading...
Page #266 background image
250 Firmware Version 6.0
SprayStar Rinse Cycle
When using the rinse cycle feature on the SprayStar, the display must have the boom sections on to
allow the SprayStar to properly run the rinse routine. To ensure that boom sections are on:
1. Enter a target rate into the display.
2. Turn the foot pedal master switch on.
3. Turn all boom switches on.
4. Boom indicators on the Run screen must be blue showing that boom valves are on.
CONTROL VALVE SETTINGS
Liquid Product Control Valve Configuration Options
• Inline Servo
Rate control is achieved through actuating a butterfly or ball valve found in the solution hose that goes to
the booms. When the valve opens, the flow increases and when the valve closes, the flow decreases.
• Bypass Servo
Rate control is achieved through actuating a butterfly or ball valve found in the return line to the solution
tank. When the valve opens, the flow decreases and when the valve closes the flow increases.
• PWM 12 volt
Rate control is achieved through speed changes to the solution pump. The PWM 12 Volt setting is
programmed to pulse the power to an electric solenoid valve used to adjust the hydraulic flow to the solution
pump.
• Pump Servo
Rate control is achieved through speed changes to the solution pump. The pump servo setting is
programmed to control an electric motor used to actuate a hydraulic valve to adjust the hydraulic flow to the
solution pump.
• PWM Ground
Rate control is achieved through speed changes to the solution pump. The PWM Ground setting is
programmed to pulse the ground to an electric solenoid valve used to adjust the hydraulic flow to the
solution pump.
• Calibrated Reflow
Three-way boom valves are used to return product back to the tank in the off state. The returned flow is
calibrated with adjustment at each valve. Calibration is required any time the nozzles are changed.
• Ramsey Valve
A pneumatically-operated bypass valve. When air is supplied to the valve the rate increases; when air is
released from the valve the rate decreases.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ag Leader Integra Display and is the answer not in the manual?

Ag Leader Integra Display Specifications

General IconGeneral
BrandAg Leader
ModelIntegra Display
CategoryMonitor
LanguageEnglish

Related product manuals